The Robust Data Transmission Cable is engineered to provide durable, high-performance, and interference-resistant data communication for industrial, commercial, and harsh environmental applications. Constructed with multi-stranded copper conductors, high-quality insulation, and reinforced shielding, this cable ensures EMI/RFI protection and stable signal integrity even under extreme mechanical stress, oil exposure, and high-temperature environments.
Its flexible yet rugged outer jacket allows installation in drag chains, cable trays, or dynamic industrial systems, making it suitable for automation networks, Ethernet systems, CNC machinery, and robotic communication setups. Compliant with CE, RoHS, UL, and ISO standards, the cable guarantees safety, durability, and long-term reliability for critical industrial applications.
Heavy-Duty Construction: Resistant to oil, abrasion, chemicals, and mechanical stress.
EMI/RFI Shielding: Ensures stable signal transmission even in high-interference industrial environments.
High Flexibility: Designed for continuous-motion applications such as drag chains or robotic arms.
Long-Term Reliability: Maintains performance under extreme temperatures and harsh conditions.
Versatile Applications: Suitable for automation, Ethernet, robotics, and CNC systems.
Certifications: CE, RoHS, UL, ISO compliant.
Customizable Options: Available in multiple conductor counts, shielding types, and jacket materials.
| Parameter | Specification |
|---|---|
| Cable Type | robust data transmission cable |
| Conductor Material | Multi-Stranded Copper (OFC) |
| Conductor Size | 24–28 AWG |
| Number of Cores | 2–32 cores (customizable) |
| Insulation Material | PE / XLPE / TPE |
| Shielding | Foil + Braided Copper |
| Outer Jacket | PVC / PUR / LSZH (oil- and abrasion-resistant) |
| Voltage Rating | 300–600V |
| Temperature Range | -40°C to +80°C |
| Data Transmission Speed | Up to 10 Gbps |
| Minimum Bending Radius | 7.5 × Cable Diameter |
| Flame Resistance | UL VW-1 / IEC 60332-1 |
| Applications | Industrial Automation, Ethernet, Robotics, CNC Machines |
| Certifications | CE, RoHS, UL, ISO9001 |
The Robust Data Transmission Cable is available in multiple specifications and models to meet diverse industrial requirements:
| Model | Conductor Count | Conductor Size | Outer Jacket Material | Maximum Transmission Speed |
|---|---|---|---|---|
| RDT-CB24 | 2–24 cores | 24 AWG | PVC | 1 Gbps |
| RDT-CB26 | 2–16 cores | 26 AWG | PUR | 2 Gbps |
| RDT-CB28 | 4–32 cores | 28 AWG | LSZH | 10 Gbps |
| RDT-FLEX | 2–12 cores | 24–28 AWG | PUR / PVC | 1–10 Gbps |
| RDT-DRAG | 2–32 cores | 24–28 AWG | PUR (oil-resistant) | 1–10 Gbps |
These models are customizable for length, shielding type, and jacket color, allowing engineers to select the perfect cable for their specific application.
Supports communication between PLCs, sensors, and actuators, ensuring real-time, reliable data transmission in production lines.
Provides high-speed, stable connectivity for industrial and commercial networking applications, including servers, routers, and switches.
Designed for dynamic motion applications, maintaining signal integrity under continuous movement in robotic arms, gantry systems, and automated guided vehicles.
Ensures precise data communication for motion controllers, servo drives, and feedback sensors, enhancing machining accuracy.
Supports high-bandwidth, low-latency data transmission for server-to-server and server-to-network communication.

Proper maintenance of Robust Data Transmission Cables ensures long-term reliability, signal integrity, and safe operation:
| Maintenance Task | Frequency | Details |
|---|---|---|
| Visual Inspection | Every 3 months | Check for cuts, abrasions, or jacket wear. |
| Connector Check | Every 6 months | Ensure connectors are tight and corrosion-free. |
| Flexibility Test | Annually | Verify cable maintains proper bending performance. |
| Electrical Testing | Annually | Measure continuity, insulation resistance, and signal integrity. |
| Replacement | Every 3–5 years | Replace if insulation is damaged or signal quality degrades. |
Tips:
Keep cables clean and free of dust, oil, or chemical exposure.
Avoid sharp bends, knots, or kinks during installation and operation.
Use cable trays, conduits, or drag chains to minimize mechanical stress.
Confirm cable specifications meet system voltage, current, and data rate requirements.
Inspect cable for mechanical damage or insulation defects.
Prepare connectors, cable supports, and drag chains.
Route the cable through drag chains or cable trays following minimum bending radius guidelines.
Secure the cable with clamps or supports to prevent movement during operation.
Connect to PLC, servo drive, or network device ensuring proper polarity and shield grounding.
Test for signal integrity, continuity, and network performance before powering the system.
Confirm smooth cable movement in dynamic applications.
Ensure connectors are tight and properly grounded.
Run system tests to verify data transmission stability.
Understanding potential faults and root causes is essential to minimize downtime:
| Issue | Possible Cause | Solution |
|---|---|---|
| Signal Loss | Damaged conductor or insulation | Inspect and replace damaged section |
| Data Corruption | EMI interference or excessive distance | Ensure proper shielding and correct cable length |
| Connector Failure | Loose, bent, or corroded connector | Tighten or replace connector |
| Reduced Flexibility | Conductor fatigue or jacket damage | Replace cable if performance degrades |
| Overheating | Exceeding voltage or current rating | Check load; replace with correctly rated cable |
Packaging: Use reels or protective coils to prevent tangling or twisting.
Storage: Keep cables in a cool, dry, and UV-protected environment.
Handling: Avoid sharp bends, kinks, and chemical exposure.
Shipping: Secure reels to prevent movement and avoid stacking heavy items on top.
“Robust cable, perfect for our robotic automation line. No signal loss even with continuous movement.”
“High durability and flexibility, handles CNC machinery vibrations very well.”
“Excellent EMI resistance, our industrial Ethernet network is stable.”
Warranty: 24 months for manufacturing defects.
Replacement: Free replacement for verified quality issues.
Technical Support: 24/7 guidance for installation, maintenance, and troubleshooting.
Custom Solutions: Available for length, conductor count, shielding, and jacket materials.
The Robust Data Transmission Cable provides durable, high-performance, and EMI-resistant signal transmission for industrial automation, Ethernet networks, robotics, CNC machinery, and data centers. Designed for heavy-duty applications, it ensures long-term reliability, flexible installation, and stable data communication. Compliant with CE, RoHS, UL, and ISO standards, it is an ideal solution for engineers, system integrators, and industrial automation professionals.
Keywords: robust data transmission cable · industrial data communication cable · high-durability network cable · heavy-duty data cable · EMI-resistant industrial cable
Choosing the right Robust Data Transmission Cable is critical for stable, high-speed, and interference-free data communication in industrial automation and network systems. Combining mechanical durability, EMI shielding, and high-performance transmission, this cable ensures efficient, safe, and long-lasting operation across robotics, CNC machinery, industrial networks, and automated production lines.
For technical consultation, custom cable orders, or installation guidance, our engineering team provides expert support, ensuring optimal performance and reliability of your data transmission infrastructure.
RELATED
این وب سایت از کوکی ها استفاده می کند تا اطمینان حاصل شود که بهترین تجربه را در وب سایت ما به دست می آورید.